Table of Contents

6.6 Fibre Reinforced Seals (FRS)

The design binder application rate is determined using the procedures for conventional sprayed seals (Section 5).

Typical rates of application for the glass fibre, and binder allowance for coating of the glass fibres are shown in Table 6.7.

Table 6.7: Typical binder allowances for glass fibre

Seal typeGlass fibre (g/m2)Binder allowance
SAM600.1 L/m2 per 30 g/m2 of fibre
SAMI90