6.6 Fibre Reinforced Seals (FRS)
The design binder application rate is determined using the procedures for conventional sprayed seals (Section 5).
Typical rates of application for the glass fibre, and binder allowance for coating of the glass fibres are shown in Table 6.7.
Seal type | Glass fibre (g/m2) | Binder allowance |
---|---|---|
SAM | 60 | 0.1 L/m2 per 30 g/m2 of fibre |